Support Blog signon

Support Blog for RPG Web Extensions / WOPiXX


In our support blog you will find descriptions and solutions of problems relating to the use of RPG Web Extensions / WOPiXX.  If you cannot find an appropriate solution, you can post your own blog question(s).

 

Registering for the Support Blog

After signing up as a Support Blog user you will receive an Email containing the login data for your personal account. You may then

 

  1. post your own support questions 
  2. modify your own support questions 
  3. comment existing support questions 
  4. edit all data in your personal account.

 

Support for registered users with Support Contract

Registered users with support contract receive expert hotline support at Toolmaker Advanced Efficiency GmbH

Tel.: +49 (0) 40-559 19 62,
Fax: +49 (0) 40-559 19 049
 


 



 

 

Geschwindigkeit von WOPiXX im Alltag

Auf unserer eigenen Maschine läuft WOPiXX 2.37 etwas langsam.
German

Auf unserer eigenen Maschine läuft WOPiXX 2.37 etwas langsam. Die gleiche Version läuft auf der http://wopixx1.rzkh.de (das Rechenzentrum ist 500 km entfernt) hingegen so flott, wie wir es uns wünschen. Am Netzwerk kann es nicht liegen, denn Internet ist nie schneller als das lokale Netzwerk. Wie können wir eine ähnlich gute Performance erreichen?

Verwendung eigener Logos in Anwendungen

Wie baue ich das Logo meiner Firma in Anwendungen ein, wenn diese an Kunden ausgeliefert werden?
German

Ich habe eine Anwendung mit Wopixx erstellt und in das Menü eingebunden. Wenn diese später an den Kunden ausgeliefert werden soll, soll im Header das Firmenlogo angezeigt werden.

Wie muß ich vorgehen? Das Handbuch hatte ich schon mal durchgeschaut, aber nichts gefunden. Sollte ich es übersehen haben reicht mir auch die Angabe wo ich's nachlesen kann.

WOPIXX manuelle Installation

Da wir (leider) mit unserer AS400 nicht direkt nach außen kommunizieren dürfen, musste ich WOPiXX (und TIM) manuell installieren. Es läuft alles, auch die DirectWeb Anwendung ... aber man kann darin nichts auswählen ...
German

wenn man den DIRWEB-Job auf der AS400 dazu anzeigt .... dann kommt:
Session-Id kann nicht ermittelt werden!                          
Cursor CSRC02 nicht geöffnet.                                    
Eigentumsrecht für Objekt PGML0200 in QTEMP Art USRSPC geändert. 
Ersetztes Objekt PGML0200 Art *USRSPC wurde in QRPLOBJ übertragen.
Eigentumsrecht für Objekt PGML0200 in QTEMP Art USRSPC geändert. 
Ersetztes Objekt PGML0200 Art *USRSPC wurde in QRPLOBJ übertragen.
Cursor §DYNCSR nicht geöffnet.                                   

WOPiXX – Invalid program identifier (WXWRKLIBH)

When launcing the option to manage library lists after an upgrade installation of WOPiXX 2.10 using an older DirectWeb environment (1.50), this error is presented: Invalid Program Identifier. Error calling WXWRKLIBH. What do I do?
English

This can happen when the library DIRWEBCGI contains a duplicate program of an older version. In this case someone, possibly years ago, copied the program WXWRKLIBH into CGI-Bibl. The old object now disrupts the utilization of the function in the browser. Please delete the stated program in DIRWEBCGI. It can only exist in DIRWEB.

 

WOPiXX Installation – Error TIM is expired

When installing WOPiXX with TIM (Toolmaker Installation Manager) I receive an error message that TIM is expired. For example, GO TIM and chose menu option 1. What do I do?
English

TIM either has not been used for many months or could not update itself and is out of date. An update is required.

 

  1. GO TIM
  2. Option 25
  3. Follow the link and download the TIM executable and install using a PC.
  4. Before installation, exit the TIM menu.

 

These instructions are also valid if TIM is corrupted.


Alternately:

 

WOPiXX licensing is unclear

When setting the WOPiXX configuration parameter on the license page, the serial numbers are not available as the page doesn’t allow them to be saved. Where do I find the serial numbers?
English

A license or serial number is not required for WOPiXX, therefore, there is nothing to save on this page. Exceptions are if additional services require licensing such as Cryptography and PDF-TET functions.

 

After saving a page, this page will remain open. You can then change to another page. The file License_WOPIXX_02_serialnumber.txt in your documentation serves as your customer registration and ascertains your support level. WOPiXX itself is not dependent on this file.

Configuring WOPiXX for HTTPS

I followed the instructions in the User Manual to establish a secure connection using HTTPS. The screenshots in the manual do not match what I see in my browser. How do I continue?
English

Even though it appears in the handbook that it is necessary to connect using HTTPS, in the beginning phase you can skip chapter 4.

 

As you can see through using the manual, the creation of a CA Certificate is a complex process which is quite difficult to master. Also, depending on IBM release, the screen display can change.


A secure connection internally is not necessarily required. Even when the user uses VPN with their browser to connect to WOPiXX, they will be in a secure environment.

WOPiXX Installation – Error when restoring the SAV file

After starting the installation using TIM, using F10 in the status display an error appears when restoring the Install file. What do I do? Die Installation mittels TIM ist gestartet, zeigt jetzt aber unter F10 in der Statusanzeige an, dass ein Fehler beim Restore der Install.-Datei aufgetreten ist. Was ist zu tun?
English

Normally TIM would handle the error, delete the file and request a new download. If that does not happen and the Order is displayed in the ERROR status, do the following:

 

WOPiXX Installed – after which there is an error in DirectMail 5.28

I have installed WOPiXX using TIM (Toolmaker Installation Manager). Now, after I have installed the newest version of DirectMail 5.28, errors using some of the DirectMail commands such as resolution to object DWCHKAPP not possible or service program DWPMWRT not found appear. How do I resolve this?
English

If you use the following steps, the problem will be solved:


1.    Register either QSECOFR or *ALLOBJ-authorization
2.    ADDLIBZLE DIRWEB
3.    CALL CHGCURDML

 

Alternatively, you can install the cumulative PTF 05 or higher from DirectMail 5.28. In both cases, all DirectMail commands (in *LIBL and DIRMAIL) will be set in the current library CURLIB on DIRWEB.

SQL – system error. Error Setting WOPIXX Environment

When starting WOPiXX for the first time after a successful installation, there is an error in the logon mask: “SQL-Systemfehler (SQL-SystemError). Error setting Wopix Environment”. In my research I found the following notice in DIRWEB CGI-Joblog: Resolution to object QICU not possible. Art and Subart X’0401’ What is QICU?
English

The following components appear to be missing on your system:

5770SS1 39 International Components for Unicode are missing in the Form of the QICU library (see GO LICPGM, menu option 10). This library provides the routines that interact with Unicode and is normally on all systems where SQL is used. This error manifests itself when SQL Unicode fields are used.

 

Please install the operating system component 39 using

GO LICPGM

menu option 11.

Pages